Structural design description::
·The frame is divided into inner frame, outer frame and high-performance thermal insulation strip.
·The inner and outer frames are made of high-strength aluminum alloy, and the surface is anodized, which is beautiful and corrosion-resistant.
The inner and outer panels are filled with PU foam with a thickness of 50mm.
After the inner and outer lining plates are formed, they are fully sprayed with plastic to effectively prevent corrosion.
The inner and outer lining plates are made of various materials, providing more choices.
·The panel and frame are connected by external screws, with high strength, convenient for disassembly and maintenance.
·The inner surface of the panel is connected by radian. The inner surface of the unit is smooth and flat, not easy to collect dust and easy to clean.
Access Door:
· The access door adopts hinge structure, the door handle adopts non-cold bridge structure design, and the door frame adopts high elastic rubber seal to fully improve the heat insulation performance of the unit and reduce the air leakage rate.
Drainage Pan:
·The drainage pan adopts the inclined dry water tray design, so that the condensed water can be easily drained.
·The surface of the drainage pan is fully sprayed to effectively prevent corrosion.
·The metal plate material configuration of the drainage pan is diverse, providing more choices.
Function Option:
Filter section: primary effect filter, medium effect filter, high efficiency filter (HEPA), chemical filter, activated carbon filter, electrostatic dust filter, plasma sterilization filter, etc.
Cooling/heating section: copper tube aluminum fin coil surface cold/heater, steel tube wound coil heater, electric heater, etc.
Fan section: belt drive double inlet centrifugal fan, direct centrifugal fan, single inlet centrifugal fan without volute, etc.;
Heat recovery section: runner chamber heat recovery device, cross-flow plate heat recovery device, heat pipe heat recovery device, etc.
Humidification section: wet film humidifier, high pressure micro fog humidifier, dry steam humidifier, electrode humidifier, electric heating humidifier, etc.
Muffler section: folding plate muffler, micro perforated plate muffler, chip muffler, impedance compound muffler, etc.
:
Unit air leakage rate: Euro standard grade L1 (Highest Grade)
Cold bridge coefficient: European standard grade TB2
Heat conduction: European Standard Grade T2 (Second Grade T2)
Filter bypass air leakage rate: European standard highest grade F9 (Highest Grade)
WIZARD Premium Combined Air Handling Units could
Optional strong and weak power integrated control cabinet.
Optional semi-embedded or machine side type.