CLIMAVENETA

Products PRODUCT
▶ Location:Home>Products> KMC Series - Centrifugal R134a
KMC Series - Centrifugal R134a
KMC Series - Centrifugal R134a
KMC Series Cooling Capacity:1759kW-10550kW CLIMAVENETA's high-efficiency two-stage centrifugal compressor frequency conversion water-cooled centrifugal chiller is the latest product, using the newly developed W3000 Chinese microcomputer controller, 13-inch large touch screen, HFC134a refrigerant, new high-efficiency heat exchanger, And the perfect combination of the economizer makes the system optimally matched. It integrates the characteristics of high efficiency, energy saving, green environmental protection, stability and reliability, and can be widely used in hotels, hospitals, enterprises, office buildings and other places. It can not only provide cold water for central air-conditioning systems in hotels, hospitals, commercial buildings, industrial and mining enterprises, etc., but also provide process cold water for textile, chemical, food, electronic scientific research and other departments.

Extended Functions:

1- Centrifugal Compressor 2- Refrigerant R134a 3-Cooling

Frame Structure Description:

1.Floor adopts outer surface of the unit has been doing polyester spraying process of galvanized steel plate, make the whole unit should not be rust.
2.Convenient, compact structure, simple unit.Easy to fully grasp the running state of unit, the evaporator and condenser in the process of transportation, room installation and daily operation effective protection effect and make the maintenance more convenient.Units inside decorate after three dimensional optimization design, layout is compact, the optimized shape proportion, need to the maintenance of the space is little, take up room area is small, save space.

Compressor Description:

1. The compressor adopts a two-stage compression belt with an intermediate economizer air supply structure, and uses a high-strength alloy main shaft, a high-strength aluminum alloy enclosed impeller, and a high-precision aviation-grade precision gear.
2. The impeller cast with special aluminum alloy is designed with the most advanced NREC centrifugal compressor design program in the world, which ensures the high precision and high efficiency of the impeller.
3. High-strength ball/roller bearings are used, which are not ordinary sliding bearings, so the compressor is not afraid of emergency stop, and a high-level oil tank is not required; start the compressor 3 seconds in advance and turn on the oil pump, so that the lubricating oil is not easy to enter the system; the start-up interval can be shortened to 8 minutes.
4. The motor and the compressor are integrated, and the flange seal is adopted, which eliminates the necessary connection and sealing device between the motor and the compressor for the open motor, reduces the wearing parts, and eliminates the problem of refrigerant leakage. Liquid refrigerant is used for evaporative cooling. , The motor temperature rise is low, the noise is low, the efficiency is high, the service life is long, and the machine room only needs general ventilation equipment.


Evaporator Description:

1.Evaporator is modified to enhance the heat transfer effect, improve system evaporation temperature, increase unit cooling capacity and improve the efficiency of the unit operation. Special technology of spray type internal structure design and reasonable evaporation space can reduce evaporation resistance. Refrigerant liquid can complete recycle without additional power by using the refrigerant flow control circulating pump. The tube cluster in evaporator can fully infiltrated and improve the heat transfer performance effectively even units are running without precisely adjusting.
2.High heat transfer efficiency of spirals inside thread copper pipe, increase the heat exchange area and refrigerant disturbance, improve the effect of heat transfer.
3.The design, manufacture and inspection of the evaporator comply with national standards and regulations for pressure vessels such as GB / 150 steel pressure vessels and JB / 4765 pressure vessels for refrigeration devices.

Condenser:

1.Shell and tube heat exchanger with efficient double thread copper pipe, increases the shell side between the refrigerant and cooling water tube side heat transfer effect.
2.Condenser uses the unique way of admission, uniform distribution of refrigerant flow, extend the condensation distance, make the heat transfer effect is best.Also increase the degree of supercooling unit, which can effectively improve the efficiency of unit cycle.
3.The design, manufacture and inspection of the evaporator comply with national standards and regulations for pressure vessels such as GB / 150 steel pressure vessels and JB / 4765 pressure vessels for refrigeration devices.

Control Cabinet:

1.The unit startup and microcomputer control parts are integrated into the same control cabinet and located at the front of the unit, which is convenient for the on-site operators to operate in the machine room and between the units. The maintenance of all electrical parts can be carried out at the front of the unit.
2.The electrical control box is made of high-quality steel plate, and the external surface has been galvanized and anti-corrosion treatment, which can effectively protect the electrical components of the unit.
3. For the safety of the operator, once the host is powered on, the operator will not be able to open the isolation board between the control and electrical components to ensure the safety of the operator.

Control System:

Certification and Honor:

Electric Control:

Cooling Capacity 1759kW-10550kW
Compressor type Centrifugal
Number of compressors 1-2
Refrigeration circuit Single/Double
Refrigerant R134a
Power Input 380V/3Ph/50Hz
Qianshan Old Village

Qianshan Old Village

Area:Guangdong
Cooling Capacity:22950kW
Period:2014
Heating Capacity:7080kW
Building Function:Residential buildings
System:
Installed Units:
1 x FOCSWATER4102 3 x FOCSWATER6004C 3 x KMC800LH 3 x PSRHH6003C-R-Y
Zhengzhou Olympic Sports Center

Zhengzhou Olympic Sports Center

Area:Henan‎
Cooling Capacity:15509kw
Period:2018
Heating Capacity:
Building Function:Sport structures
System:
Installed Units:
1 x KMC-1100LY-INV 1 x KMC1100LY 2 x KMC-1100LY-D 1 x CCS0500-INV 2 x CCS0500-INV 2 x FOCSWATER2501
Overall integrated R&D design experiment building

Overall integrated R&D design experiment building

Area:Beijing‎
Cooling Capacity:12500KW
Period:2019
Heating Capacity:
Building Function:Office Buildings
System:
Installed Units:
3 x FOCSWATER2602-INV 3 x CCS0900F1-INV"
huairou hospitai phase II

huairou hospitai phase II

Area:Beijing
Cooling Capacity:6100kW
Period:2021
Heating Capacity:
Building Function:Healthcare / Hospitals
System:
Installed Units:
2x TECS-W7504L-E 1x FOCSWATER2451E "
Tra Vinh Hospital

Tra Vinh Hospital

Area:Vietnam
Cooling Capacity:5100 kW
Period:2020
Heating Capacity:
Building Function:Healthcare / Hospitals
System:
Installed Units:
3×FOCSWATER 4952E 505 ×FCU
Learn More > >

Products

PRODUCT
KMC Series - Centrifugal R134a
KMC Series - Centrifugal R134a Water-cooled Centrifugal Chiller
KMC Series Cooling Capacity:1759kW-10550kW CLIMAVENETA's high-efficiency two-stage centrifugal compressor frequency conversion water-cooled centrifugal chiller is the latest product, using the newly developed W3000 Chinese microcomputer controller, 13-inch large touch screen, HFC134a refrigerant, new high-efficiency heat exchanger, And the perfect combination of the economizer makes the system optimally matched. It integrates the characteristics of high efficiency, energy saving, green environmental protection, stability and reliability, and can be widely used in hotels, hospitals, enterprises, office buildings and other places. It can not only provide cold water for central air-conditioning systems in hotels, hospitals, commercial buildings, industrial and mining enterprises, etc., but also provide process cold water for textile, chemical, food, electronic scientific research and other departments.
特点
CLIMAVENETA
  • Features
  • Technical Data
  • Projects
  • Download
  • Other

Extended Functions:

1- Centrifugal Compressor 2- Refrigerant R134a 3-Cooling

Frame Structure Description:

1.Floor adopts outer surface of the unit has been doing polyester spraying process of galvanized steel plate, make the whole unit should not be rust.
2.Convenient, compact structure, simple unit.Easy to fully grasp the running state of unit, the evaporator and condenser in the process of transportation, room installation and daily operation effective protection effect and make the maintenance more convenient.Units inside decorate after three dimensional optimization design, layout is compact, the optimized shape proportion, need to the maintenance of the space is little, take up room area is small, save space.

Compressor Description:

1. The compressor adopts a two-stage compression belt with an intermediate economizer air supply structure, and uses a high-strength alloy main shaft, a high-strength aluminum alloy enclosed impeller, and a high-precision aviation-grade precision gear.
2. The impeller cast with special aluminum alloy is designed with the most advanced NREC centrifugal compressor design program in the world, which ensures the high precision and high efficiency of the impeller.
3. High-strength ball/roller bearings are used, which are not ordinary sliding bearings, so the compressor is not afraid of emergency stop, and a high-level oil tank is not required; start the compressor 3 seconds in advance and turn on the oil pump, so that the lubricating oil is not easy to enter the system; the start-up interval can be shortened to 8 minutes.
4. The motor and the compressor are integrated, and the flange seal is adopted, which eliminates the necessary connection and sealing device between the motor and the compressor for the open motor, reduces the wearing parts, and eliminates the problem of refrigerant leakage. Liquid refrigerant is used for evaporative cooling. , The motor temperature rise is low, the noise is low, the efficiency is high, the service life is long, and the machine room only needs general ventilation equipment.


Evaporator Description:

1.Evaporator is modified to enhance the heat transfer effect, improve system evaporation temperature, increase unit cooling capacity and improve the efficiency of the unit operation. Special technology of spray type internal structure design and reasonable evaporation space can reduce evaporation resistance. Refrigerant liquid can complete recycle without additional power by using the refrigerant flow control circulating pump. The tube cluster in evaporator can fully infiltrated and improve the heat transfer performance effectively even units are running without precisely adjusting.
2.High heat transfer efficiency of spirals inside thread copper pipe, increase the heat exchange area and refrigerant disturbance, improve the effect of heat transfer.
3.The design, manufacture and inspection of the evaporator comply with national standards and regulations for pressure vessels such as GB / 150 steel pressure vessels and JB / 4765 pressure vessels for refrigeration devices.

Condenser:

1.Shell and tube heat exchanger with efficient double thread copper pipe, increases the shell side between the refrigerant and cooling water tube side heat transfer effect.
2.Condenser uses the unique way of admission, uniform distribution of refrigerant flow, extend the condensation distance, make the heat transfer effect is best.Also increase the degree of supercooling unit, which can effectively improve the efficiency of unit cycle.
3.The design, manufacture and inspection of the evaporator comply with national standards and regulations for pressure vessels such as GB / 150 steel pressure vessels and JB / 4765 pressure vessels for refrigeration devices.

Control Cabinet:

1.The unit startup and microcomputer control parts are integrated into the same control cabinet and located at the front of the unit, which is convenient for the on-site operators to operate in the machine room and between the units. The maintenance of all electrical parts can be carried out at the front of the unit.
2.The electrical control box is made of high-quality steel plate, and the external surface has been galvanized and anti-corrosion treatment, which can effectively protect the electrical components of the unit.
3. For the safety of the operator, once the host is powered on, the operator will not be able to open the isolation board between the control and electrical components to ensure the safety of the operator.

Control System:

Certification and Honor:

Electric Control:

Cooling Capacity 1759kW-10550kW
Compressor type Centrifugal
Number of compressors 1-2
Refrigeration circuit Single/Double
Refrigerant R134a
Power Input 380V/3Ph/50Hz
Changji Yanyue Bay

Changji Yanyue Bay

Area:Henan Period:2018 Building Function:Residential buildings System: Cooling Capacity:11111.5kW Heating Capacity:14642.7kW
Installed Units:

1 x PSRHH4802-Y-R 1 x PSRHH4502-Y-R 1 x PSRHH5103 1 x PSRHH5003.C-Y 1 x PSRHH9004.C-Y 3x PSRHH2401M

Qianshan Old Village

Qianshan Old Village

Area:Guangdong Period:2014 Building Function:Residential buildings System: Cooling Capacity:22950kW Heating Capacity:7080kW
Installed Units:

1 x FOCSWATER4102 3 x FOCSWATER6004C 3 x KMC800LH 3 x PSRHH6003C-R-Y

Zhengzhou Olympic Sports Center

Zhengzhou Olympic Sports Center

Area:Henan‎ Period:2018 Building Function:Sport structures System: Cooling Capacity:15509kw Heating Capacity:
Installed Units:

1 x KMC-1100LY-INV 1 x KMC1100LY 2 x KMC-1100LY-D 1 x CCS0500-INV 2 x CCS0500-INV 2 x FOCSWATER2501

Five Pine Ice Sports Center

Five Pine Ice Sports Center

Area:Beijing‎ Period:2019 Building Function:Sport structures System: Cooling Capacity:4600kW Heating Capacity:
Installed Units:

3 x TECS-W4503L-E

‎State Grid Chongqing Zhiwang Science and Technology Comprehensive Office Building‎

‎State Grid Chongqing Zhiwang Science and Technology Comprehensive Office Building‎

Area:Chongqing‎ Period:2021 Building Function:Office Buildings System: Cooling Capacity:4800kW Heating Capacity:5000kW
Installed Units:

2 x ERACS3622E-N-D-B 1 x ERACS3602E-N-B 2 x ERACS3622E-N-B 52 x MFC 900 x FCU