CLIMAVENETA

Products PRODUCT
▶ Location:Home>Products> IN-ROW AC Series - Air-Cooled DX
IN-ROW AC Series - Air-Cooled DX
IN-ROW AC Series - Air-Cooled DX
CRCK-IC/CRCX-IC series Cooling capacity: 9.3kW-55.3kW The rack cooler air conditioner is used to solve the cooling problem in the high heat density area of the computer room and as an auxiliary refrigeration device to solve the local hot spot problem in the computer room. climaveneta air-cooled rack cooler air conditioners, all series of standard high-efficiency scroll or brushless DC inverter compressors, low-noise EC fans, CAREL's new generation controller, and electronic expansion valves make the unit have the best cooling performance. The whole system also supports a variety of installation schemes for up and down pipes and up and down wiring. The frame of the unit is 300mm and 600mm, and the size of the unit can be customized according to the project requirements

Extended Functions:

Frame Structure Description:

The overall frame and bottom plate of the unit are made of galvanized steel sheet whose outer surface has been electrostatically sprayed, so that the unit as a whole is not suitable for rusting. The unit structure is convenient and compact, occupies a small area of the machine room, saves space, and the unit supports full frontal maintenance. In the electric control box of the unit, the strong and weak currents are separated, and the high-power components such as electric heating and humidification are equipped with independent circuit breakers. The unit supports upper and lower pipes and upper and lower wiring, which is convenient for installation.

Compressor Description:

High reliability design, can choose frequency scroll or DC inverter compressor. The compressor has the characteristics of high energy efficiency ratio, COP≥3.0, small starting current, small vibration of the unit, low noise, and has motor overload protection. The fixed frequency series adopts the American Copeland high-efficiency scroll compressor, and the variable frequency series adopts well-known brand compressors such as Mitsubishi or Danfoss.The cooling capacity of the inverter compressor is adjusted more accurately, and the temperature control accuracy can reach ±0.5℃.

Evaporator Description:

The evaporator has a unique surface treatment (hydrophilic), and adopts special water treatment to solve the problem of condensed water droplets entering the air duct. The evaporator has a large area, and the fin material is specially treated, so it does not stick to water, the heat exchange effect is good, and the air pressure drop before and after the evaporator is small. Meet the requirements of the international ASTM D572799 standard. With stainless steel drain pan.

Condenser:

The condenser has a unique surface treatment (hydrophilic), and adopts special water treatment to solve the problem of condensed water droplets entering the air duct. The condenser has a large area, and the fin material is specially treated, so it does not stick to water and has a good heat exchange effect. Meet the requirements of the international ASTM D572799 standard.

 

Control Cabinet:

It is placed on the top of the unit (can be pulled out) or the upper end of the fan, and supports frontal maintenance of electrical components, which is simple and convenient.

Control System:

Using the new generation of CAREL controller, it has a good man-machine interface, excellent control adjustment function, strong expansion ability, monitoring and management ability and strong compatibility. Multiple expansion accessories to increase remote and group control functions. 1. Friendly man-machine interface: The operation screen is embedded in the unit, which is convenient for operation and good protection. Fully computerized automatic control to realize unmanned operation. Intuitive LCD interface, multi-language and multi-menu display data and parameter adjustment, can display the operating status and temperature and humidity parameters of the main components such as the compressor, and the operation status is clear at a glance. 2. Unit control and operation management: advanced microcomputer intelligent control system, built-in control algorithm specially designed by climaveneta, more prominent energy saving and reliability of the unit, can realize the functions such as round-robin, standby machine self-starting, etc. Change the main control strategy to control the unit based on the return air temperature; 3. Network communication and building control functions: support building control connections. 4. Fault protection, alarm and analysis capabilities The microcomputer intelligent controller has perfect fault protection, alarm, recording and analysis functions, and has protection functions such as high and low voltage switches, phase loss, overload, overcurrent, overheating, and exhaust temperature, and realizes The fault record and alarm display can record 100 faults for fault diagnosis after the fault occurs, quickly eliminate the fault, and improve the technical support effect.


Lightning protection module:

The lightning protection requirements of climaveneta rack cooler air conditioners meet the requirements of class C in YD5098-2005, and the class C anti-surge devices specified in the standard are selected. The surge protection device can at least withstand voltage pulses (10/700μs, 5kV) and Impulse of current pulse (8/20 μs, 5 kA). The equipment used should be products that have passed the test of the Ministry of Industry and Information Technology.

Dehumidification function:

climaveneta rack cooler air conditioners have a low-load dehumidification function, and the unit can still dehumidify reliably under low-load conditions.


Certification and Honor:

Electric Control:

Cooling Capacity 9.3-55.3kw
Compressor type Scroll/DC Inverter
Number of compressors 1
Refrigerant R410a
Power Input 220V/1N/50Hz380V/3N/50Hz
Beijing Huitianyun Project

Beijing Huitianyun Project

Area:Beijing
Cooling Capacity:58980kW
Period:2016
Heating Capacity:
Building Function:Data Center
System:
Installed Units:
194 x SCU100 36 x SCU025 191 x SCU140
State Grid Corporation Beijing Disaster Recovery Center

State Grid Corporation Beijing Disaster Recovery Center

Area:Beijing
Cooling Capacity:11040kW
Period:2014
Heating Capacity:
Building Function:Data Center
System:
Installed Units:
12 x SCU120 48 x SCU200
Beijing Sinnet Technology Co., Ltd.

Beijing Sinnet Technology Co., Ltd.

Area:Shanghai
Cooling Capacity:12710kW
Period:2015
Heating Capacity:
Building Function:Data Center
System:
Installed Units:
82 x SCU155B
China Unicom National Data Center Beijing Yizhuang IDC room

China Unicom National Data Center Beijing Yizhuang IDC room

Area:Beijing
Cooling Capacity:2120kW
Period:2012
Heating Capacity:
Building Function:Data Center
System:
Installed Units:
23×DWU080F 23×BDC103 3×DWU060F 3×BDC078 2×DWU050F 2×BDC062
BEIJING SINNET TECHNOLOGY CO., LTD.  (2015)

BEIJING SINNET TECHNOLOGY CO., LTD. (2015)

Area:Beijing
Cooling Capacity:7248kW
Period:2015
Heating Capacity:
Building Function:Data Center
System:
Installed Units:
48×SCU100 12×SCU160
Learn More > >

Products

PRODUCT
IN-ROW AC Series - Air-Cooled DX
IN-ROW AC Series - Air-Cooled DX air cooled rack cooler HPAC
CRCK-IC/CRCX-IC series Cooling capacity: 9.3kW-55.3kW The rack cooler air conditioner is used to solve the cooling problem in the high heat density area of the computer room and as an auxiliary refrigeration device to solve the local hot spot problem in the computer room. climaveneta air-cooled rack cooler air conditioners, all series of standard high-efficiency scroll or brushless DC inverter compressors, low-noise EC fans, CAREL's new generation controller, and electronic expansion valves make the unit have the best cooling performance. The whole system also supports a variety of installation schemes for up and down pipes and up and down wiring. The frame of the unit is 300mm and 600mm, and the size of the unit can be customized according to the project requirements
特点
CLIMAVENETA
  • Features
  • Technical Data
  • Projects
  • Download
  • Other

Extended Functions:

Frame Structure Description:

The overall frame and bottom plate of the unit are made of galvanized steel sheet whose outer surface has been electrostatically sprayed, so that the unit as a whole is not suitable for rusting. The unit structure is convenient and compact, occupies a small area of the machine room, saves space, and the unit supports full frontal maintenance. In the electric control box of the unit, the strong and weak currents are separated, and the high-power components such as electric heating and humidification are equipped with independent circuit breakers. The unit supports upper and lower pipes and upper and lower wiring, which is convenient for installation.

Compressor Description:

High reliability design, can choose frequency scroll or DC inverter compressor. The compressor has the characteristics of high energy efficiency ratio, COP≥3.0, small starting current, small vibration of the unit, low noise, and has motor overload protection. The fixed frequency series adopts the American Copeland high-efficiency scroll compressor, and the variable frequency series adopts well-known brand compressors such as Mitsubishi or Danfoss.The cooling capacity of the inverter compressor is adjusted more accurately, and the temperature control accuracy can reach ±0.5℃.

Evaporator Description:

The evaporator has a unique surface treatment (hydrophilic), and adopts special water treatment to solve the problem of condensed water droplets entering the air duct. The evaporator has a large area, and the fin material is specially treated, so it does not stick to water, the heat exchange effect is good, and the air pressure drop before and after the evaporator is small. Meet the requirements of the international ASTM D572799 standard. With stainless steel drain pan.

Condenser:

The condenser has a unique surface treatment (hydrophilic), and adopts special water treatment to solve the problem of condensed water droplets entering the air duct. The condenser has a large area, and the fin material is specially treated, so it does not stick to water and has a good heat exchange effect. Meet the requirements of the international ASTM D572799 standard.

 

Control Cabinet:

It is placed on the top of the unit (can be pulled out) or the upper end of the fan, and supports frontal maintenance of electrical components, which is simple and convenient.

Control System:

Using the new generation of CAREL controller, it has a good man-machine interface, excellent control adjustment function, strong expansion ability, monitoring and management ability and strong compatibility. Multiple expansion accessories to increase remote and group control functions. 1. Friendly man-machine interface: The operation screen is embedded in the unit, which is convenient for operation and good protection. Fully computerized automatic control to realize unmanned operation. Intuitive LCD interface, multi-language and multi-menu display data and parameter adjustment, can display the operating status and temperature and humidity parameters of the main components such as the compressor, and the operation status is clear at a glance. 2. Unit control and operation management: advanced microcomputer intelligent control system, built-in control algorithm specially designed by climaveneta, more prominent energy saving and reliability of the unit, can realize the functions such as round-robin, standby machine self-starting, etc. Change the main control strategy to control the unit based on the return air temperature; 3. Network communication and building control functions: support building control connections. 4. Fault protection, alarm and analysis capabilities The microcomputer intelligent controller has perfect fault protection, alarm, recording and analysis functions, and has protection functions such as high and low voltage switches, phase loss, overload, overcurrent, overheating, and exhaust temperature, and realizes The fault record and alarm display can record 100 faults for fault diagnosis after the fault occurs, quickly eliminate the fault, and improve the technical support effect.


Lightning protection module:

The lightning protection requirements of climaveneta rack cooler air conditioners meet the requirements of class C in YD5098-2005, and the class C anti-surge devices specified in the standard are selected. The surge protection device can at least withstand voltage pulses (10/700μs, 5kV) and Impulse of current pulse (8/20 μs, 5 kA). The equipment used should be products that have passed the test of the Ministry of Industry and Information Technology.

Dehumidification function:

climaveneta rack cooler air conditioners have a low-load dehumidification function, and the unit can still dehumidify reliably under low-load conditions.


Certification and Honor:

Electric Control:

Cooling Capacity 9.3-55.3kw
Compressor type Scroll/DC Inverter
Number of compressors 1
Refrigerant R410a
Power Input 220V/1N/50Hz380V/3N/50Hz
Changji Yanyue Bay

Changji Yanyue Bay

Area:Henan Period:2018 Building Function:Residential buildings System: Cooling Capacity:11111.5kW Heating Capacity:14642.7kW
Installed Units:

1 x PSRHH4802-Y-R 1 x PSRHH4502-Y-R 1 x PSRHH5103 1 x PSRHH5003.C-Y 1 x PSRHH9004.C-Y 3x PSRHH2401M

Qianshan Old Village

Qianshan Old Village

Area:Guangdong Period:2014 Building Function:Residential buildings System: Cooling Capacity:22950kW Heating Capacity:7080kW
Installed Units:

1 x FOCSWATER4102 3 x FOCSWATER6004C 3 x KMC800LH 3 x PSRHH6003C-R-Y

Zhengzhou Olympic Sports Center

Zhengzhou Olympic Sports Center

Area:Henan‎ Period:2018 Building Function:Sport structures System: Cooling Capacity:15509kw Heating Capacity:
Installed Units:

1 x KMC-1100LY-INV 1 x KMC1100LY 2 x KMC-1100LY-D 1 x CCS0500-INV 2 x CCS0500-INV 2 x FOCSWATER2501

Five Pine Ice Sports Center

Five Pine Ice Sports Center

Area:Beijing‎ Period:2019 Building Function:Sport structures System: Cooling Capacity:4600kW Heating Capacity:
Installed Units:

3 x TECS-W4503L-E

‎State Grid Chongqing Zhiwang Science and Technology Comprehensive Office Building‎

‎State Grid Chongqing Zhiwang Science and Technology Comprehensive Office Building‎

Area:Chongqing‎ Period:2021 Building Function:Office Buildings System: Cooling Capacity:4800kW Heating Capacity:5000kW
Installed Units:

2 x ERACS3622E-N-D-B 1 x ERACS3602E-N-B 2 x ERACS3622E-N-B 52 x MFC 900 x FCU